How often do temperature data loggers need recalibration and/or servicing?
HOBO data loggers are manufactured using precision components. As long as the data loggers are not damaged or exposed to conditions outside of their operating environment, they should maintain their...
-
HOBO RX3000 Cable Channel Kit Assembly Installation
Learn how to install the RX3000 Cable Channel Kit
-
U30 and excitation wiring with S-VIA-CM14 modules
Here is a wiring diagram for use with external sensors and the S-VIA-CM14s. Remember the excitation current required to power the external sensors cannot exceed 50 milliamps total. http://www...
-
Wireline mounting a U20 water level data logger in a well
HOBO Water Level data loggers can be hung in wells using Onset's special low-stretch cable with Teflon coating, to avoid snagging and to make them easy to clean. Materials You may require one...
-
Wiring Diagram - HOBO RX3000 - RXMOD-A1 Voltage Input Logic Switch
Attached is a wiring diagram that shows how to monitor switch closures with an HOBO RX3000 via the optional RXMO
-
Adding or Removing Smart Sensors from a HOBO RX3000 Station
To add or remove smart sensors from a HOBO RX3000 station: 1. If the station is currently logging, press the Stop button to stop it. 2. Press the Connect button and wait for the station to...
-
Making beaded probes on a thermocouple wire
A thermocouple is a kind of battery made by joining two dissimilar metals together where a small voltage is generated by the difference between the metals. The voltage generated changes with...
-
How to reconfigure your S-FS-TRMSA-D Module for use with an RX3000 Station
See how to reconfigure your TRMS module for use with an RX3000
-
Wiring Diagram - Monitoring a 3-Phase Circuit with the HOBO RX3000 Station and T-VER-E50B2
Attached is a wiring diagram that shows you how to connect the T-VER-E50B2 Power and Energy Meter to the HOBO RX3000 Station. Note: The T-VER-E50B2 ouputs pulses representing Watt/hours,...
-
Calibrating ECH2O Soil Moisture Sensors Application Note
Onset adds smart sensor adapters to the ECH2O probes so that they are plug‐and‐play compatible with HOBO® U30 stations and HOBO Micro Stations. The S‐SMC‐M005 incorporates the EC‐5 and the S‐SMD‐M005...
-
Logging RH without Temp
The Bluetooth-enabled HOBO MX1101 and HOBO MX1102 loggers both use a Relative Humidity sensor that returns a temperature-compensated RH measurement. USB loggers, such as the HOBO UX100-03, use an...
-
Wiring Diagram - Monitoring Single-phase AC Current using the HOBO UX120-006M
Attached is a drawing that shows how to measure AC current through a line cord using the HOBO UX120-006M 4-channel Analog Input logger and a CTV-A current transformer. Note: This drawing is...