[{"sku":"UX120-006M","title":"HOBO 4-Channel Analog Data Logger","subtitle":null,"variant_product_name":null,"unit_price":"225.00","brands":["HOBO"],"region":null,"service_plans":[],"parcel_length":"3.00","parcel_width":"1.50","parcel_height":"4.25","parcel_weight":"0.25","sellable":true,"published":true,"product_page_url":"\/products\/data-loggers\/ux120-006m","nid":"12686","product_description":"<p>A high-performance, LCD display data logger, supporting up to four external sensors to measure and record parameters such as temperature, current, voltages, and third-party sensors. This logger is ideal for energy audits, building commissioning studies, equipment scheduling, and more.<\/p>\r\n","applications":["Building Performance","HVAC\/R Monitoring Systems for Indoor Environmental Quality (IAQ & IEQ)","Indoor Environment","Construction Compliance"],"brand":"HOBO","communication":"USB","compatibility_callout":["HOBOware"],"compatible_items":{"Communications":{"Communication_Cables":{"items":["CABLE-USBMB"]}},"Required Software":{"Software":{"items":["BHW-PRO-DLD","BHW-PRO-USB"]}},"Sensor":{"420_mA":{"items":["CABLE-4-20MA"]},"AC_Current":{"items":["CTV-A","CTV-B","CTV-C","CTV-D","CTV-E"]},"AC_Voltage":{"items":["T-CON-ACT-150","T-CON-ACT-300"]},"Air_Velocity":{"items":["T-DCI-F300-1A3","T-DCI-F300-1B3","T-DCI-F300-1C3","T-DCI-F350-W5A3","T-DCI-F350-W5B3","T-DCI-F350-W5C3"]},"DC_Amperage":{"items":["T-VER-971BP-200"]},"DC_Voltage":{"items":["CABLE-2.5-STEREO","CABLE-ADAP5","CABLE-ADAP10","CABLE-ADAP24"]},"Differential_Pressure":{"items":["T-VER-PX3UL"]},"Gauge_Pressure":{"items":["T-ASH-G2-100","T-ASH-G2-200","T-ASH-G2-500"]},"Temperature":{"items":["TMC1-HD","TMC6-HD","TMC20-HD","TMC50-HD","TMC6-HC","TMC6-HE"]}},"Accessory":{"Compliance_Certificates":{"items":["COMPLIANCE CERT"]},"NIST_Setup_Certifications":{"items":["NIST-SETUP","NIST-TEMP-POINT"]},"Accessories":{"items":["ME-BP"]}}},"country":"US","customers_also_bought":["HOBOware","CABLE-DCVOLT","CABLE-4-20MA"],"field_documents":[{"nid":9611},{"nid":10061}],"environment":["Indoor"],"important_information":"External sensors sold separately. Requires HOBOware software and a USB cable. (Note: A USB-A to USB-B mini cable is included w\/HOBOware Pro USB Drive software purchase). See compatible items below.","logger_sensor_type":"external_sensors","measurement":["4-20mA ","AC Current ","AC Voltage ","Air Velocity ","Carbon Dioxide ","Compressed Air Flow ","DC Current ","DC Voltage ","Differential Pressure ","Gauge Pressure ","Kilowatts (kW) ","Temperature "],"media_remote_videos":["https:\/\/www.youtube.com\/watch?v=5A0h4N892mE"],"not_a_sku":"0","page_type":"add-to-cart","parcel_status":"default","product_battery":"2AAA","product_family_series":"UX120","features":"<ul>\n\t<li>Twice the accuracy of previous models with 16-bit resolution<\/li>\n\t<li>Flexible support for a wide range of external sensors<\/li>\n\t<li>LCD confirms logger operation and displays near real-time measurement data<\/li>\n\t<li>Provides minimum, maximum, average, and standard deviation logging options<\/li>\n\t<li>On-screen alarms notify you when a sensor reading exceeds set thresholds<\/li>\n\t<li>Stores 1.9 million measurements for longer deployments between offloads<\/li>\n\t<li>Compatible with HOBOware and HOBOware Pro software for logger setup and graphing & analysis<\/li>\n<\/ul>\n","product_price":"225.00","specifications":[{"type":"Simple text","revision_default":"1","field_description":"<p><u><strong>Logger w\/Cable<\/strong><\/u><\/p>\n\n<p><strong>Measurement Range<\/strong>:<br>\n4-20mA (w\/<a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"37ef1791-bf96-4cb8-a6d4-a547631a3b47\" href=\"\/products\/cables\/cable-4-20ma\" title=\"CABLE-4-20MA\">CABLE-4-20MA<\/a>) 0 to 20.1 mA<br>\n0 to 2.5 V (w\/<a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-2.5-STEREO<\/a>)<br>\n0 to 5 V (w\/<a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-ADAP5<\/a>)<br>\n0 to 10 V (w\/ <a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-ADAP10<\/a>)<br>\n0 to 24 V (w\/ <a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-ADAP24<\/a>)<\/p>\n\n<p><strong>Accuracy:<\/strong><br>\n4-20mA \u00b10.001 mA \u00b10.2% of reading (w\/<a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"37ef1791-bf96-4cb8-a6d4-a547631a3b47\" href=\"\/products\/cables\/cable-4-20ma\" title=\"CABLE-4-20MA\">CABLE-4-20MA<\/a>)<br>\n\u00b10.1 mV \u00b10.1% of reading (w\/<a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-2.5-STEREO<\/a>)<br>\n\u00b10.2 mV \u00b10.3% of reading (w\/<a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"2b72be58-ad56-4f57-8079-a3db6fccd59a\" href=\"\/products\/cables\/cable-adap5\">CABLE-ADAP5<\/a>)<br>\n\u00b10.4 mV \u00b10.3% of reading (w\/ <a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-ADAP10<\/a>)<br>\n\u00b11.0 mV \u00b10.3% of reading(w\/ <a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-ADAP24<\/a>)<\/p>\n\n<p> <\/p>\n\n<p><strong>Resolution:<\/strong><br>\n0.3 \u00b5A 4-20mA (w\/<a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"37ef1791-bf96-4cb8-a6d4-a547631a3b47\" href=\"\/products\/cables\/cable-4-20ma\" title=\"CABLE-4-20MA\">CABLE-4-20MA<\/a>)<br>\n40 \u00b5V (w\/<a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-2.5-STEREO<\/a>)<br>\n80 \u00b5V (w\/<a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"2b72be58-ad56-4f57-8079-a3db6fccd59a\" href=\"\/products\/cables\/cable-adap5\">CABLE-ADAP5<\/a>)<br>\n160 \u00b5V (w\/ <a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-ADAP10<\/a>)<br>\n384 \u00b5V (w\/ <a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"54a81363-b551-4802-ade2-6c4de553eba1\" href=\"\/products\/sensors\/cable-dcvolt\" title=\"CABLE-DCVOLT\">CABLE-ADAP24<\/a>)<\/p>\n\n<p><u><strong>Logger<\/strong><\/u><\/p>\n\n<p><strong>Operating range logging:<\/strong> -20\u00b0 to 70\u00b0C (-4\u00b0 to 158\u00b0F); 0 to 95% RH (non-condensing);<br>\n<strong>Launch\/readout: <\/strong>0\u00b0 to 50\u00b0C (32\u00b0 to 122\u00b0F) per USB specification<br>\n<strong>Logging rate:<\/strong> 1 second to 18 hours, 12 minutes, 15 seconds<br>\n<strong>Logging modes:<\/strong> Normal, burst, or statistics<br>\n<strong>Memory modes:<\/strong> Wrap when full or stop when full<br>\n<strong>Start modes:<\/strong> Immediate, push button, date & time, or next interval<br>\n<strong>Stop modes<\/strong>: When memory full, push button, or date & time<br>\n<strong>Restart mode:<\/strong> Push button<br>\n<strong>Time accuracy:<\/strong> \u00b11 minute per month at 25\u00b0C (77\u00b0F), see Plot A<br>\n<strong>Battery life:<\/strong> 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater<br>\n<strong>Battery type:<\/strong> Two AAA 1.5 V alkaline batteries, user replaceable<br>\n<strong>Memory:<\/strong> 4 MB (1.9 million measurements, maximum)<br>\n<strong>Download type:<\/strong> USB 2.0 interface<br>\n<strong>Full memory download time:<\/strong> approximately 1.5 minutes<br>\n<strong>LCD:<\/strong> LCD is visible from 0\u00b0 to 50\u00b0C (32\u00b0 to 122\u00b0F); the LCD may react slowly or go blank in temperatures outside this range<br>\n<strong>Size:<\/strong> 10.8 x 5.41 x 2.54 cm (4.25 x 2.13 x 1 in.)<br>\n<strong>Weight:<\/strong> 107.5 g (3.79 oz)<br>\n<strong>Environmental rating:<\/strong> IP50<\/p>\n\n<p> <\/p>\n\n<p> <\/p>\n\n<article class=\"media media--type-image media--view-mode-default media--orientation-unset\" data-embed-button=\"embed_image\">\n \n \n <div class=\"field field--name-field-media-image field--type-image field--label-visually_hidden\">\n <div class=\"field__label visually-hidden\">Image<\/div>\n <div class=\"field__item field__item__odd field__item__first field__item__last\"> <img loading=\"lazy\" src=\"\/sites\/default\/files\/embedded-product-images\/CE.jpg\" width=\"24\" height=\"19\" alt=\"Description: ce\" typeof=\"foaf:Image\" class=\"img-fluid\">\n\n<\/div>\n <\/div>\n\n <\/article>\n\n\n<p>- The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).<\/p>\n\n<p> <\/p>\n"}],"product_status":"active","product_type":"Data Loggers","search_keys":"analog input","solution":["Stand-alone Data Loggers ","Stand-alone USB Data Loggers "],"summary_cta":"Get your data without the wires!Upgrade to an MX1105Same accurate data\u2014Simpler, Time-Saving Bluetooth Offload, basic_html","upgrade_options":["MX1105"],"warranty":"1","warranty_premium":"1","whats_in_the_box":["HOBO UX120-006M 4-Channel Analog Data Logger","Command\u2122 strip","Double-sided tape","Hook & loop strap","Two AAA 1.5 V alkaline batteries"],"wireless":"non_wireless","digital_item":"0"},[{"nid":"9611","uuid":"e658b230-07ae-4926-9509-1f3bc6969120","vid":"10456","langcode":"und","revision_timestamp":"1645725746","status":"1","title":"HOBO 4-Channel Analog Data Logger (UX120-006M) User's Manual","created":"1389100554","changed":"1645725746","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/17384-c-ux120-006m-manual","pid":"18716","langcode":"und"},"archive_resource":"0","associated_products":["UX120-006M"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/17384-E%20UX120-006M%20Manual.pdf","German":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/18526-B%20UX120-006M%20Manual%20German.pdf","Japanese":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/18527-A%20UX120-006M%20Manual%20Japanese.pdf"},"documentation_id":"17384-C-UX120-006M-Manual","documentation_is_datasheet":"0","resource_type":"Documentation"},{"nid":"10061","uuid":"3c862735-42d9-4aa0-8b43-52b043a7688a","vid":"10906","langcode":"und","revision_timestamp":"1645725720","status":"1","title":"Quick Start for the HOBO\u00ae U-Series Data Logger","created":"1462555541","changed":"1645725720","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/16125-man-u-qsg-web","pid":"20046","langcode":"und"},"archive_resource":"0","associated_products":["U12-001","U12-006","U12-008","U12-011","U12-012","U12-013","U12-014","U12-015","U12-015-02","U12-015-03","U14-001","U14-002","UX100-001","UX100-003","UX100-011A","UX100-014M","UX100-023A","UX120-006M","UX120-014M","UX120-017","UX120-017M","UX120-018","UX90-001","UX90-001M-RETIRED","UX90-002","UX90-004","UX90-004M-RETIRED","UX90-005x","UX90-005M-RETIRED","UX90-006","UX90-006M-RETIRED"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/2023-03\/16125-F%20MAN-U-QSG-web.pdf","German":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/20691-B%20MAN-U-QSG-G-web.pdf"},"documentation_id":"16125-MAN-U-QSG-web","documentation_is_datasheet":"0","resource_type":"Documentation"}]]
UX120-006M
HOBO 4-Channel Analog Data Logger
A high-performance, LCD display data logger, supporting up to four external sensors to measure and record parameters such as temperature, current, voltages, and third-party sensors. This logger is ideal for energy audits, building commissioning studies, equipment scheduling, and more.