[{"sku":"S-FS-TRMSA-D","title":"FlexSmart TRMS Module (2 channels) w\/modular plug Sensor","subtitle":null,"variant_product_name":null,"unit_price":"155.00","brands":["HOBO"],"region":null,"service_plans":[],"parcel_length":"3.00","parcel_width":"1.50","parcel_height":"4.25","parcel_weight":"0.15","sellable":true,"published":true,"product_page_url":"\/products\/sensors\/s-fs-trmsa-d","nid":"12331","product_description":"<p>A 15-bit two-channel module, with modular plug, that accepts an input range of 5mV to 512mV and is compatible with 333mV FS output sensors. Field wiring is 2-wire via screw terminals.<\/p>\r\n\r\n<p><strong>IMPORTANT NOTES:<\/strong><\/p>\r\n\r\n<ul>\r\n\t<li>If using the S\u2010FS\u2010TRMSA\u2010D with a U30\u2010GSM or RX3003-00-01, RX3004 or RX2100, the S\u2010FS\u2010TRMSA\u2010D should be located approximately 1 meter (3 ft) from the cellular station to avoid interference from the GSM radio. Use Smart Sensor extension cable Onset part # <a href=\"\/products\/cables\/s-ext-m002\">S\u2010EXT\u2010M002<\/a>.<\/li>\r\n<\/ul>\r\n\r\n<ul>\r\n\t<li>If using the S\u2010FS\u2010TRMSA\u2010D with a RX2100 or RX3004 and you are using both the TRMSA-D modules and smart sensors, then you are limited to a maximum of 2 TRMSA-D and any combination of smart sensors to reach a total of 13 data channels. For example, if there are two (2) TRMSA-D modules (4 data channels) in use with the RX3000 or RX2100 station, then this will leave nine (9) additional data channels for smart sensors.<\/li>\r\n<\/ul>\r\n","add_on_products":{"items":["ZIP-KIT"]},"applications":["Building Performance","HVAC\/R Monitoring Systems for Indoor Environmental Quality (IAQ & IEQ)","Energy Monitoring"],"brand":"HOBO","compatible_items":{"Accessory":{"Compliance_Certificates":{"items":["COMPLIANCE CERT"]}},"Additional Compatible Products":{"Sensors":{"items":["T-MAG-0400-05","T-MAG-0400-20","T-MAG-0400-50","T-MAG-0400-75"]}},"Communications":{"Extension_Cables":{"items":["S-EXT-M002"]}},"Data Logger":{"USB_Data_Loggers_requires_external_sensors":{"items":["H22-001","U30-NRC"]},"USB_w_external_sensors":{"items":["U30-NRC-SYS-C"]},"Web_based_Monitoring_Systems_via_remote_communication":{"items":["RX3000"]}},"Sensor":{"AC_Current":{"items":["T-ACT-0750-020","T-ACT-0750-050","T-ACT-0750-100","T-ACT-0750-250","T-MAG-SCT-100","T-MAG-SCT-200","T-MAG-SCT-600"]},"AC_Voltage":{"items":["T-MAG-SPT-150","T-MAG-SPT-300","T-MAG-SPT-600"]}}},"country":"US","customers_also_bought":["S-ADAPT-6","S-EXT-M002"],"field_documents":[{"nid":8811},{"nid":9631}],"environment":["Indoor"],"measurement":["AC Current ","AC Voltage "],"not_a_sku":"0","parcel_status":"default","features":"<ul>\n\t<li>2 input channels of AC Current and\/or Voltage<\/li>\n\t<li>Measures True RMS for accurate readings of sinusoidal and non-sinusoidal waveforms<\/li>\n<\/ul>","product_price":"155.00","specifications":[{"type":"Simple text","revision_default":"1","field_description":"<style type=\"text\/css\">.specs-table .bolded, .specs-table td[data-colnum='1'] {\n font-weight:700;\n}\n.specs-table tr.header {\n background-color: lightgrey; \n}\n<\/style>\n<table border=\"0\" cellpadding=\"7\" cellspacing=\"0\" class=\"specs-table\" data-maxcols=\"2\" data-rows=\"13\" data-table-text-header=\"Specifications\" style=\"width:100%\">\n\t<tbody>\n\t\t<tr data-cols=\"2\" data-firstrow=\"1\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Input Channels<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">Two; AC-coupled<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Field Wiring<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">Two-wire via screw terminals on detachable connector, 16-24 AWG<br>\n\t\t\tReplacement detachable connectors: Part of spares kit (A-FS-TRMSA-4P-1)<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Input Range<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">5 to 512 mVRMS<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Minimum Input Voltage<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">5mVRMS; Input voltages < 5mV will be clipped to zero (see graph below)<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Maximum Input Voltage<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">\u00b11V referred to AC- terminals (pins 2 and 4)<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Input Frequency<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">50\/60 Hz<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Accuracy<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">\u00b10.3% of reading +\/- 0.5% of FSR<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">ADC Resolution<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">15 bits<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">AC Waveform<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\"><4 Crest Factor<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Power Requirements<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">+3.3V @ 3mA active, 6A sleep<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Transfer Function<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\"><p><\/p><article class=\"media media--type-image media--view-mode-default media--orientation-unset\" data-embed-button=\"embed_image\">\n \n \n <div class=\"field field--name-field-media-image field--type-image field--label-visually_hidden\">\n <div class=\"field__label visually-hidden\">Image<\/div>\n <div class=\"field__item field__item__odd field__item__first field__item__last\"> <img loading=\"lazy\" src=\"\/sites\/default\/files\/embedded-product-images\/S-FS-TRMSA-VRMS-Function.png\" width=\"572\" height=\"158\" alt typeof=\"foaf:Image\" class=\"img-fluid\">\n\n<\/div>\n <\/div>\n\n <\/article>\n<\/td>\n\t\t<\/tr>\n\t\t<tr data-cols=\"2\">\n\t\t\t<td class=\"bolded\" data-colnum=\"1\" valign=\"top\">Measurement Averaging Option<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">Yes<\/td>\n\t\t<\/tr>\n\t\t<tr class=\"ce-mark\" data-cols=\"2\">\n\t\t\t<td data-colnum=\"1\" valign=\"top\"><p><\/p><article class=\"media media--type-image media--view-mode-default media--orientation-unset\" data-embed-button=\"embed_image\" data-width=\"24\" data-height=\"19\">\n \n \n <div class=\"field field--name-field-media-image field--type-image field--label-visually_hidden\">\n <div class=\"field__label visually-hidden\">Image<\/div>\n <div class=\"field__item field__item__odd field__item__first field__item__last\"> <img loading=\"lazy\" src=\"\/sites\/default\/files\/embedded-product-images\/CE.jpg\" width=\"24\" height=\"19\" alt=\"Description: ce\" typeof=\"foaf:Image\" class=\"img-fluid\">\n\n<\/div>\n <\/div>\n\n <\/article>\n<\/td>\n\t\t\t<td colspan=\"1\" data-colnum=\"2\">The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).<\/td>\n\t\t<\/tr>\n\t<\/tbody>\n<\/table>"}],"product_status":"active","product_type":"Sensors","warranty":"1","warranty_premium":"1","digital_item":"0"},[{"nid":"8811","uuid":"d29665bb-401f-42de-ac0b-2215a04563f1","vid":"9656","langcode":"und","revision_timestamp":"1645725778","status":"1","title":"Using FlexSmart TRMS Module (2 channels) w\/modular plug Sensor (S-FS-TRMSA-D) with HOBO U30 Cellular Data Logger (U30-GSM) Special Note","created":"1251835072","changed":"1645725778","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/13394-b-man-trmsad-u30gsm","pid":"16881","langcode":"und"},"archive_resource":"0","associated_products":["S-FS-TRMSA-D","U30-GSM"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/13394-B-MAN-TRMSAD-U30GSM.pdf"},"documentation_id":"13394-B-MAN-TRMSAD-U30GSM","resource_type":"Documentation"},{"nid":"9631","uuid":"c363e429-1a30-4da1-9865-b5b0ea7d5589","vid":"10476","langcode":"und","revision_timestamp":"1645725827","status":"1","title":"FlexSmart TRMS Module (S-FS-TRMSA, S-FS-TRMSA-D) Quick Start Guide","created":"1188404739","changed":"1645725827","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/10093-man-s-fs-trmsa","pid":"18756","langcode":"und"},"archive_resource":"0","associated_products":["S-FS-TRMSA","S-FS-TRMSA-D"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/2023-04\/10093-J%20MAN-S-FS-TRMSA.pdf"},"documentation_id":"10093-MAN-S-FS-TRMSA","documentation_is_datasheet":"0","resource_type":"Documentation"}]]
A 15-bit two-channel module, with modular plug, that accepts an input range of 5mV to 512mV and is compatible with 333mV FS output sensors. Field wiring is 2-wire via screw terminals.
IMPORTANT NOTES:
If using the S‐FS‐TRMSA‐D with a U30‐GSM or RX3003-00-01, RX3004 or RX2100, the S‐FS‐TRMSA‐D should be located approximately 1 meter (3 ft) from the cellular station to avoid interference from the GSM radio. Use Smart Sensor extension cable Onset part # S‐EXT‐M002.
If using the S‐FS‐TRMSA‐D with a RX2100 or RX3004 and you are using both the TRMSA-D modules and smart sensors, then you are limited to a maximum of 2 TRMSA-D and any combination of smart sensors to reach a total of 13 data channels. For example, if there are two (2) TRMSA-D modules (4 data channels) in use with the RX3000 or RX2100 station, then this will leave nine (9) additional data channels for smart sensors.