HOBO RX3000 and the TRMSA-D FlexSmart Module
{"nid":"7221","uuid":"5b594685-799b-43f2-b01a-90d14a770f79","vid":"26351","langcode":"und","revision_timestamp":"1666909159","status":"1","title":"HOBO RX3000 and the TRMSA-D FlexSmart Module ","created":"1531773712","changed":"1692131347","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/tech-notes\/hobo-rx3000-and-the-trmsa-d-flexsmart-module","pid":"13906","langcode":"und"},"body":"<p>If you are using both TRMSA-D FlexSmart modules and smart sensors with your HOBO RX3000 station, you are limited to a maximum of three TRMSA-D modules and any combination of smart sensors to reach a total of 13 data channels.<\/p>\r\n\r\n<p>For example:<\/p>\r\n\r\n<ul>\r\n\t<li>If there are three TRMSA-D modules in use with the RX3000 station (each module has two channels for a total of six in all), then this will leave seven additional data channels for smart sensors<\/li>\r\n<\/ul>\r\n\r\n<p>Similarly:<\/p>\r\n\r\n<ul>\r\n\t<li>If there are two TRMSA-D modules in use with the RX3000 station, this will leave nine additional data channels for smart sensors.<\/li>\r\n<\/ul>\r\n\r\n<p>Refer to the smart sensor manuals at www.onsetcomp.com\/support\/manuals for the number of data channels used by a specific smart sensor. If you are not using smart sensors with the HOBO RX3000 station, then you are limited to a maximum of four TRMSA-D modules. Exceeding these guidelines may result in erroneous readings.<\/p>\r\n","applications":["Environmental Research & Protection","Agricultural Monitoring"],"archive_resource":"0","associated_products":["RX2100","RX210xxxx-RETIRED","RX2100-WL","RX3000","RX3004-SYS-KIT-813","S-FS-TRMSA","S-FS-TRMSA-D"],"brand":"HOBO","documentation_hoboconnect":"0","documentation_intemp_app":"0","documentation_is_datasheet":"0","meta_tags":"a:1:{s:6:\"robots\";s:7:\"noindex\";}","resource_topic":["Getting Started","Troubleshooting & Maintenance"],"resource_type":"Tech Note","tech_note_audience":["External"],"tech_note_type":["Measurement and accuracy"]}
If you are using both TRMSA-D FlexSmart modules and smart sensors with your HOBO RX3000 station, you are limited to a maximum of three TRMSA-D modules and any combination of smart sensors to reach a total of 13 data channels.
For example:
- If there are three TRMSA-D modules in use with the RX3000 station (each module has two channels for a total of six in all), then this will leave seven additional data channels for smart sensors
Similarly:
- If there are two TRMSA-D modules in use with the RX3000 station, this will leave nine additional data channels for smart sensors.
Refer to the smart sensor manuals at www.onsetcomp.com/support/manuals for the number of data channels used by a specific smart sensor. If you are not using smart sensors with the HOBO RX3000 station, then you are limited to a maximum of four TRMSA-D modules. Exceeding these guidelines may result in erroneous readings.