[{"sku":"CX402-Txxx","title":"InTemp Temperature Storage Monitoring with Probe in Glycol","subtitle":"Multi-use Bluetooth digital data logger with LCD and probe in glycol bottle","variant_product_name":"4M Probe with 30ml Glycol Bottle (pharma storage) - T430","unit_price":"190.00","brands":["InTemp"],"region":null,"service_plans":[],"parcel_length":"5.00","parcel_width":"1.50","parcel_height":"5.50","parcel_weight":"0.40","sellable":true,"published":true,"product_page_url":"\/intemp\/products\/data-loggers\/cx402-txxx","nid":"13001","product_description":"<p>InTemp<span style=\"color:rgb(37, 37, 37); font-family:sans-serif; font-size:14px\"> <\/span>CX402-Txxx (with Glycol Bottle) data loggers monitor temperatures in refrigerators, freezers and other temperature-controlled environments to comply with global GDP requirements. The loggers communicate wirelessly via Bluetooth to mobile devices. Using the InTemp app, you can easily view data, check logger status, set alarms, and create and share secure PDF reports for streamlined reporting and regulatory compliance. All loggers feature a built-in LCD display to view current and daily min and max temperatures, advanced audible and visual alarm capabilities for notification of temperature excursions, an internal sensor for ambient temperature monitoring, and a single-point NIST Certification of Calibration for both the logger body and probe.<\/p>\r\n\r\n<p>With the optional CX Gateway, you can get remote notifications of temperature excursions and automatically download data from loggers within range of the device. Learn more about the <a href=\"\/intemp\/products\/communications\/cx5000\" rel=\"noopener\" target=\"_blank\">CX Gatewa<\/a><a href=\"\/intemp\/products\/communications\/cx5000\">y<\/a> here.<\/p>\r\n\r\n<p>Models are available with a 2- or 4-meter external temperature probe attached to a Glycol bottle used to insulate the probe and delay thermal response times.<\/p>\r\n","applications":["Cold Chain Shipping and Logistics","Transportation & Logistics","Clinical Trials","Storage Monitoring & Logistics Solutions","Blood & Plasma Storage & Logistics","Pharmaceutical\/Vaccine Storage","Hospitals, Clinics, and Pharmacies","Vaccines for Children\/CDC"],"brand":"InTemp","communication":"Bluetooth (mobile device or web via CX Gateway)","compliance_marks":["Conformit\u00e9 Europ\u00e9ene (CE)","Federal Communications Commission (FCC)","Regulatory Compliance Mark (RCM)","Japanese Telecommunication and Radio Certification"],"country":"US","field_documents":[{"nid":10106},{"nid":10116},{"nid":10121}],"environment":["Cold Chain"],"important_information":"Remote monitoring, process automation, and alarm notifications require the CX5001 Gateway. Gateway and mobile devices must be within 100ft (30.5m) Bluetooth range for data transmission. , basic_html","logger_sensor_type":"int_ext_sensors","measurement":["Temperature "],"message_boxes":"287481, 1800621","not_a_sku":"0","parcel_status":"default","product_family_series":"CX","features":"<h3> <\/h3>\n\n<h3>Who is this for?<\/h3>\n\n<p>The InTemp CX402-Txxx data logger (with probe in glycol) is right for you if:<\/p>\n\n<ul>\n\t<li>You work for an organization that\u2019s required to primarily follow GDP\/GMP, FDA, USP, and\/or EU\/CE guidelines for monitoring ambient to frozen temperatures<\/li>\n\t<li>Your organization is a pharmaceutical manufacturer, third-party logistics company, Life Science\/Biotech storage and transportation company, or other organization looking to monitor temperature-sensitive goods<\/li>\n\t<li>You need a 1-Year NIST-certified data logger (probe and ambient temperature sensor), as recommended by the previously mentioned regulatory bodies<\/li>\n<\/ul>\n\n<p>Required to follow GDP & GMP requirements, specifically:<\/p>\n\n<ul>\n\t<li>Probe in glycol<\/li>\n\t<li>GDP\/GMP compliant<\/li>\n\t<li>Frozen to ambient monitoring<\/li>\n<\/ul>\n","specifications":[{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"External Temperature Probe","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Accuracy","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"\u00b11.8\u00b0F from -40\u00b0 to -13\u00b0F","field_spec_metric_value":"\u00b11.0\u00b0C from -40\u00b0 to -25\u00b0C"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"\u00b10.9\u00b0F from -13\u00b0 to 176\u00b0F","field_spec_metric_value":"\u00b10.5\u00b0C from -25\u00b0 to 80\u00b0C"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"\u00b11.8\u00b0F from 176\u00b0 to 212\u00b0F","field_spec_metric_value":"\u00b11.0\u00b0C from 80\u00b0 to 100\u00b0C"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Resolution","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"0.04\u00b0F at 77\u00b0F","field_spec_metric_value":"0.024\u00b0C at 25\u00b0C"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Operating Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"-40\u00b0 to 212\u00b0F","field_spec_metric_value":"-40\u00b0 to 100\u00b0C"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"NIST Calibration","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"CX40x-Txx and CX402-BxM: Single point NIST calibration, probe and logger body"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"CX40x-VFCxxx: Single point NIST calibration, probe only"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"CX403: Single point NIST calibration"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Cable Length","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"2 or 4 meter (6.56 or 13.12 feet) flat ribbon cable"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Probe Dimensions","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Food-grade stainless steel probe with pointed tip, 53.34 mm (2.1 inches) long, 3.18 mm (0.125 inches) diameter"}]}]},{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"Temperature Sensor","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"-22\u00b0 to 158\u00b0F","field_spec_metric_value":"-30\u00b0 to 70\u00b0C"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Accuracy","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"\u00b10.9\u00b0F from 5\u00b0 to 158\u00b0F","field_spec_metric_value":"\u00b10.5\u00b0C from -15\u00b0 to 70\u00b0C"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"\u00b11.8\u00b0F from -22\u00b0 to 5\u00b0F","field_spec_metric_value":"\u00b11.0\u00b0C from -30\u00b0 to -15\u00b0C"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Resolution","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"0.04\u00b0F at 77\u00b0F","field_spec_metric_value":"0.024\u00b0C at 25\u00b0C"}]}]}]},{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"Logger","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Radio Power","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"0 dBm","field_spec_metric_value":"1 mW"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Transmission Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Approximately 30.5 m (100 ft) line-of-sight"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Wireless Data Standard","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Bluetooth Low Energy (Bluetooth Smart)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Logger Operating Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"-22\u00b0 to 158\u00b0F, 0 to 95% RH (non-condensing)","field_spec_metric_value":"-30\u00b0 to 70\u00b0C, 0 to 95% RH (non-condensing)"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Logging Rate","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"1 second to 18 hours"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Battery Type","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Two AAA batteries, user replaceable"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Battery Life","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive report generation, numerous audible alarms, and paging all impact battery life."}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Memory","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"128 KB (84,650 measurements, maximum)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Full Memory Download Time","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Approximately 60 seconds; may take longer the farther the device is from the logger"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"LCD","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"LCD is visible from 0\u00b0 to 50\u00b0C (32\u00b0 to 122\u00b0F); the LCD may react slowly or go blank in temperatures outside this range"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Dimensions","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"3.7 x 1.77 x 1.02 inches","field_spec_metric_value":"9.4 x 4.5 x 2.59 cm"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Weight","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"3.18 oz","field_spec_metric_value":"90.2 g"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Environmental Rating","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"IP54"}]}]},{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"1","field_hide_on_specs_tab":"0","field_specification_group_label":"Notices","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"BLANK","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Passed RTCA DO160G, part 21H"}]}]}],"product_status":"active","product_type":"Data Loggers","product_variants":{"variation_label":"probe length and glycol bottle volume","items":[{"sku":"CX402-T205","title":"2M Probe with 5ml Glycol Bottle (vaccine storage) - T205","variation":"2M Probe with 5ml Glycol Bottle","variant_status":"active","price":"190.00","non_shippable":false},{"sku":"CX402-T215","title":"2M Probe with 15ml Glycol Bottle (pharma storage) - T215","variation":"2M Probe with 15ml Glycol Bottle","variant_status":"active","price":"190.00","non_shippable":false},{"sku":"CX402-T230","title":"2M Probe with 30ml Glycol Bottle (pharma storage) - T230","variation":"2M Probe with 30ml Glycol Bottle","variant_status":"active","price":"190.00","non_shippable":false},{"sku":"CX402-T405","title":"4M Probe with 5ml Glycol Bottle (vaccine storage) - T405","variation":"4M Probe with 5ml Glycol Bottle","variant_status":"active","price":"199.00","non_shippable":false},{"sku":"CX402-T415","title":"4M Probe with 15ml Glycol Bottle (pharma storage) - T415","variation":"4M Probe with 15ml Glycol Bottle","variant_status":"active","price":"199.00","non_shippable":false},{"sku":"CX402-T430","title":"4M Probe with 30ml Glycol Bottle (pharma storage) - T430","variation":"4M Probe with 30ml Glycol Bottle","variant_status":"active","price":"199.00","non_shippable":false}]},"related_resources":["InTemp Data Loggers: Getting Started Video"],"summary_cta":" ","warranty":"0","digital_item":"0"},[{"nid":"10106","uuid":"dd56d9ec-ddae-4f9f-a981-2bfd21badf9d","vid":"45191","langcode":"und","revision_timestamp":"1676650672","status":"1","title":"InTemp CX Temperature Logger (CX40x) Manual","created":"1472491811","changed":"1676650876","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/intemp\/resources\/documentation\/19996-cx40x-manual","pid":"20181","langcode":"und"},"body":"<p>InTemp CX400 series loggers measure temperature in indoor monitoring applications. Designed to meet World Health Organization (WHO) and Centers for Disease Control and Prevention (CDC) guidelines, this logger is ideal for clinical applications, such as vaccine storage and pharmaceutical manufacturing.<\/p>\r\n","archive_resource":"0","associated_products":["CX402-Txxx","CX402-VFCxxx","CX402-xxM","CX403"],"brand":"InTemp","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/2023-06\/19996-X%20CX40x%20Manual.pdf"},"documentation_hoboconnect":"0","documentation_id":"19996-CX40x-Manual","files":{"documentation_image":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources\/intemp-cx400-logger.png","media_image":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources\/intemp-cx400-logger.png"},"documentation_intempseries":"cx400","documentation_intemp_app":"1","documentation_is_datasheet":"0","documentation_pages":"intemp_cx","documentation_short_title":"CX Manual","hoboconnect_docs_sorting":"0","hobomobile_docs_sorting":"0","intemp_cx_docs_sorting":"-16","resource_type":"Documentation"},{"nid":"10116","uuid":"4bd3c35b-06f1-4ea9-a9b5-2e458d9570d0","vid":"94231","langcode":"und","revision_timestamp":"1749176215","status":"1","title":"InTemp System User\u2019s Guide","created":"1472492575","changed":"1749176215","promote":"0","sticky":"1","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/intemp\/resources\/documentation\/20000-intemp-system-users-guide","pid":"20211","langcode":"und"},"body":"<p>CX series loggers, the InTemp\u00ae app, and InTempConnect\u2122 web-based software work together to form the InTemp temperature monitoring solution.<\/p>\r\n","archive_resource":"0","associated_products":["CX402-Txxx","CX402-VFCxxx","CX402-xxM","CX403","CX405","CX450","CX5001","CX501","CX502","CX503","CX602","CX603","CX702","CX703"],"brand":"InTemp","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/2025-06\/20000-AM%20InTemp%20System%20User%27s%20Guide.pdf"},"documentation_hoboconnect":"0","documentation_id":"20000-InTemp-System-Users-Guide","files":{"documentation_image":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources\/InTemp-Covid-Data-Logger-Group.jpg","media_image":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources\/InTemp-Covid-Data-Logger-Group.jpg"},"documentation_intemp_app":"1","documentation_is_datasheet":"0","documentation_pages":"intemp_cx","documentation_short_title":"InTemp App Manual","hoboconnect_docs_sorting":"0","hobomobile_docs_sorting":"0","intemp_cx_docs_sorting":"-20","resource_type":"Documentation"},{"nid":"10121","uuid":"54a38dab-7312-497e-ab67-a2a363a95690","vid":"35761","langcode":"und","revision_timestamp":"1669153221","status":"1","title":"InTemp VFC CX402 Data Sheet","created":"1472496352","changed":"1669153221","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/intemp\/resources\/documentation\/intemp-vfc-cx402-data-sheet","pid":"20221","langcode":"und"},"body":"<p>The new InTemp CX400-VFC Series is a family of high-performance data loggers for monitoring temperatures in refrigerators, freezers, and other temperature-controlled environments.<\/p>\r\n","archive_resource":"0","associated_products":["CX402-VFCxxx"],"brand":"InTemp","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/Onset-InTemp-VFC-data-sheet_0.pdf"},"documentation_hoboconnect":"0","documentation_id":"InTemp-VFC-CX402-Data-Sheet","files":{"documentation_image":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources\/datasheets.png","media_image":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources\/datasheets.png"},"documentation_intempseries":"cx400","documentation_intemp_app":"0","documentation_is_datasheet":"1","resource_type":"Documentation"}]]
CX402-Txxx
InTemp Temperature Storage Monitoring with Probe in Glycol
InTempCX402-Txxx (with Glycol Bottle) data loggers monitor temperatures in refrigerators, freezers and other temperature-controlled environments to comply with global GDP requirements. The loggers communicate wirelessly via Bluetooth to mobile devices. Using the InTemp app, you can easily view data, check logger status, set alarms, and create and share secure PDF reports for streamlined reporting and regulatory compliance. All loggers feature a built-in LCD display to view current and daily min and max temperatures, advanced audible and visual alarm capabilities for notification of temperature excursions, an internal sensor for ambient temperature monitoring, and a single-point NIST Certification of Calibration for both the logger body and probe.
With the optional CX Gateway, you can get remote notifications of temperature excursions and automatically download data from loggers within range of the device. Learn more about the CX Gateway here.
Models are available with a 2- or 4-meter external temperature probe attached to a Glycol bottle used to insulate the probe and delay thermal response times.