[{"sku":"H22-001","title":"HOBO H22 Energy Data Logger","subtitle":"Multi-Channel Data Logger","variant_product_name":null,"unit_price":"510.00","brands":["HOBO"],"region":null,"service_plans":[],"parcel_length":"6.00","parcel_width":"3.75","parcel_height":"9.00","parcel_weight":"1.45","sellable":true,"published":true,"product_page_url":"\/products\/data-loggers\/h22-001","nid":"11346","product_description":"<p>This 15-channel data logger lets energy and facility managers monitor energy and industrial equipment to quickly and easily detect and address a variety of issues relating to HVAC, machinery, and other systems. A modular device, the HOBO H22-001 Energy Data Logger is more economical than its alternatives because it eliminates the need for a toolbox full of data loggers.<\/p>\r\n\r\n<p>Deploying this logger with a variety of pre-defined plug-and-play smart sensors create a robust monitoring system, and it's compatible with <a href=\"\/products\/software\/hoboware\" rel=\"noopener\" target=\"_blank\">HOBOware software<\/a>, so researchers can conduct effective data analysis in minutes.<\/p>\r\n","applications":["Building Performance","HVAC\/R Monitoring Systems for Indoor Environmental Quality (IAQ & IEQ)","Energy Monitoring","Indoor Environment"],"brand":"HOBO","communication":"USB","compatibility_callout":["HOBOware"],"compatible_items":{"Required Software":{"Graphing_Analysis":{"items":["BHW-PRO-DLD","BHW-PRO-USB"]}},"Sensor":{"420_mA":{"items":["S-CIA-CM14"]},"AC_Current":{"items":["T-ACT-0750-020","T-ACT-0750-050","T-ACT-0750-100","T-ACT-0750-250","T-MAG-0400-05","T-MAG-0400-20","T-MAG-0400-50","T-MAG-0400-75","T-MAG-SCT-100","T-MAG-SCT-200","T-MAG-SCT-600"]},"AC_Voltage":{"items":["T-MAG-SPT-150","T-MAG-SPT-300","T-MAG-SPT-600"]},"Air_Velocity":{"items":["T-DCI-F300-1A3","T-DCI-F300-1B3","T-DCI-F300-1C3","T-DCI-F350-W5A3","T-DCI-F350-W5B3","T-DCI-F350-W5C3"]},"Barometric_Pressure":{"items":["S-BPA-CM10","S-BPB-CM50"]},"DC_Current":{"items":["T-VER-971BP-200"]},"DC_Voltage":{"items":["S-FS-CVIA","S-VIA-CM14"]},"Differential_Pressure":{"items":["T-VER-PX3UL"]},"Gauge_Pressure":{"items":["T-ASH-G2-100","T-ASH-G2-200","T-ASH-G2-500"]},"Kilowatt_Hours":{"items":["T-WNB-3D-240","T-WNB-3D-480","T-WNB-3Y-208","T-WNB-3Y-208-P"]},"Light_Intensity":{"items":["S-LIA-M003","S-LIB-M003"]},"Pulse_Input":{"items":["S-UCC-M001","S-UCC-M006","S-UCD-M001","S-UCD-M006"]},"Rainfall":{"items":["S-RGA-M002","S-RGB-M002"]},"Relative_Humidity":{"items":["S-THC-M002","S-THC-M008"]},"Temperature":{"items":["S-TMB-M002","S-TMB-M006","S-TMB-M017"]},"Water_Flow":{"items":["T-MINOL-130-NL"]},"Wind":{"items":["S-WDA-M003","S-WSB-M003","S-WSET-B"]}},"Communications":{"Communication_Cables":{"items":["ADAPT-SER-USB","CABLE-PC-3.5"]}},"Maintenance":{"Batteries":{"items":["HWSB-LI"]},"Spares_Kit":{"items":["A-H22-SPARES-1"]}},"Accessory":{"AC_Power":{"items":["P-AC-1"]},"Cable_Adapters_Splitter":{"items":["S-ADAPT-5","S-ADAPT-6"]},"Compliance_Certificates":{"items":["COMPLIANCE CERT"]},"Mounting_Accessories":{"items":["A-H22-DINMOUNT-1","A-H22-MOUNT-1"]},"Accessories":{"items":["ME-BP"]}}},"country":"US","customers_also_bought":["S-FS-CVIA","S-FS-TRMSA","T-WNB-3D-240","UX120-018"],"field_documents":[{"nid":9341}],"environment":["Indoor"],"important_information":"External sensors sold separately. Requires HOBOware software and part # ADAPT-SER-USB interface cables. See compatible items below.","logger_sensor_type":"external_sensors","measurement":["4-20mA ","AC Current ","AC Voltage ","Air Velocity ","Amp Hour (Ah) ","Carbon Dioxide ","Compressed Air Flow ","DC Current ","DC Voltage ","Dew Point ","Differential Pressure ","Gauge Pressure ","Kilowatt Hours (kWh) ","Kilowatts (kW) ","Power Factor (PF) ","Pulse Input ","Relative Humidity ","Temperature ","Volt-Amp Reactive ","Volt-Amp Reactive hour ","Volt-Amps (VA) ","Water Flow ","Watt Hours (Wh) ","Watts (W) "],"not_a_sku":"0","parcel_status":"default","product_battery":"8AA","product_family_series":"H22","features":"<ul style=\"line-height: 20.7999992370605px;\">\n\t<li>Flexible data logger records up to 15 channels of more than a dozen measurements<\/li>\n\t<li>Provides 12v excitation for third-party sensors<\/li>\n\t<li>Pre-configured Smart Sensors get you started fast<\/li>\n\t<li>Signal conditioning modules retain configurations until you change them, providing plug-and-play convenience for commonly used sensors<\/li>\n\t<li>Flexible power options include battery operation for AC power adapter<\/li>\n<\/ul>\n","product_price":"510.00","specifications":[{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"No category","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Operating range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"-4\u00b0 to 122\u00b0F with alkaline batteries","field_spec_metric_value":"-20\u00b0 to 50\u00b0C with alkaline batteries"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"-40\u00b0 to 140\u00b0F with lithium batteries","field_spec_metric_value":"-40\u00b0 to 60\u00b0C with lithium batteries"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Sensor inputs","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Three FlexSmart multi-channel modules and up to 6 Smart Sensors (which may have multiple parameters\/channels)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Sensor connectors","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Six RJ-12 Smart Sensor jacks plus 3 FlexSmart module slots"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Communication","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"RS-232 via 3.5 mm serial port or\/and 9-pin D-Sub connector"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Dimensions","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"6.13\" x 3.31\" x 1.81\"","field_spec_metric_value":"15.6 cm x 8.4 cm x 4.6 cm"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Weight","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"15.23 oz with batteries","field_spec_metric_value":"435 g with batteries"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"8.33 oz without batteries","field_spec_metric_value":"238 g without batteries"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Memory","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"512K nonvolatile flash data storage"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Memory modes","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Stop when full; wrap when full"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Operational indicators","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Six indicators provide logging and sensor network status"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Logging interval","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"One second to 18 hours, user-specified interval (2-second minimum for two-channel S-FS-TRMSA operation)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Sensor excitation","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"12\u00a0V DC at 200\u00a0mA total, with user-programmable warmup time on a per-channel basis"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Battery life","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"One year typical use (up to 75\u00a0mA excitation with 10-minute or longer logging Interval and 1-second warmup time)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Battery type","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"Eight standard AA alkaline batteries included (for operating conditions -4\u00b0F to 122\u00b0F)","field_spec_metric_value":"Eight standard AA alkaline batteries included (for operating conditions -20\u00b0C to 50\u00b0C)"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"Optional AA lithium batteries available for operating conditions of -40\u00b0 to 140\u00b0F.","field_spec_metric_value":"Optional AA lithium batteries available for operating conditions of -40\u00b0 to 60\u00b0C."}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"External power","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Supports optional 13.6 V DC regulated AC Wall Adapter Connector. Internal batteries may remain installed. Alternatively, an automotive battery or 9-12 V DC regulated Wall Adapter may be used, but it is recommended to remove the internal batteries since they will discharge to the level of the external supply."}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Time accuracy","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"0 to 2 seconds for the first data point and \u00b15 seconds per week at 77\u00b0F","field_spec_metric_value":"0 to 2 seconds for the first data point and \u00b15 seconds per week at 25\u00b0C"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Logging mode","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Immediate, timed delay, or trigger (button-push) start options; supports sampling intervals for some sensors"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Data communication","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Current readings while logging; read out while logging; read out when stopped"}]}]},{"type":"Simple text","revision_default":"1","field_description":"<div style=\"display:inline-block;\">\n<article class=\"media media--type-image media--view-mode-default media--orientation-unset\" style=\"float:left; margin-right:2rem;\" data-mark=\"CE\">\n \n \n <div class=\"field field--name-field-media-image field--type-image field--label-visually_hidden\">\n <div class=\"field__label visually-hidden\">Image<\/div>\n <div class=\"field__item field__item__odd field__item__first field__item__last\"> <img loading=\"lazy\" src=\"\/sites\/default\/files\/2022-10\/ce-mark.png\" width=\"27\" height=\"19\" alt=\"CE Compliance Mark\" typeof=\"foaf:Image\" class=\"img-fluid\">\n\n<\/div>\n <\/div>\n\n <\/article>\n\n<\/div>"}],"product_status":"active","product_type":"Data Loggers","search_keys":"analog input, amps","solution":["Stand-alone Multi-Sensor Stations "],"warranty":"1","warranty_premium":"1","whats_in_the_box":["HOBO H22-001 Energy Logger","Eight 1.5V alkaline batteries","1 miniature slotted screwdriver","Blank label","Rubber feet"],"wireless":"non_wireless","digital_item":"0"},[{"nid":"9341","uuid":"e4702abb-1f86-4659-9100-b3d1be2b7198","vid":"74866","langcode":"und","revision_timestamp":"1715880368","status":"1","title":"HOBO Energy Logger (H22-001) User's Guide","created":"1188330482","changed":"1715880368","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","path":{"alias":"\/resources\/documentation\/9857-man-h22-web","pid":"18046","langcode":"und"},"archive_resource":"0","associated_products":["H22-001"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/9857-I%20MAN-H22-web.pdf"},"documentation_hoboconnect":"0","documentation_id":"9857-MAN-H22-web","documentation_intemp_app":"0","documentation_is_datasheet":"0","hoboconnect_docs_sorting":"0","hobomobile_docs_sorting":"0","intemp_cx_docs_sorting":"0","resource_type":"Documentation"}]]
H22-001
HOBO H22 Energy Data Logger
This 15-channel data logger lets energy and facility managers monitor energy and industrial equipment to quickly and easily detect and address a variety of issues relating to HVAC, machinery, and other systems. A modular device, the HOBO H22-001 Energy Data Logger is more economical than its alternatives because it eliminates the need for a toolbox full of data loggers.
Deploying this logger with a variety of pre-defined plug-and-play smart sensors create a robust monitoring system, and it's compatible with HOBOware software, so researchers can conduct effective data analysis in minutes.
Compatible with
Not sure this is the right logger?
Compare Loggers
Talk to an Application Expert
Specifications
Documents
Compatible Items
What's Included
Customers Also Bought
Frequently Asked Questions
Related Products
Related Resources
Recently Viewed
!