[{"sku":"U24-002-C","title":"HOBO Saltwater Conductivity\/Salinity Data Logger","subtitle":"Salt Water","variant_product_name":null,"unit_price":"1075.00","brands":["HOBO"],"region":null,"service_plans":[],"parcel_length":"5.00","parcel_width":"1.50","parcel_height":"5.50","parcel_weight":"0.50","sellable":true,"published":true,"product_page_url":"\/products\/data-loggers\/u24-002-c","nid":"12441","product_description":"<p>A cost-effective data logger for measuring salinity, conductivity, and temperature in saltwater environments with relatively small changes in salinity (\u00b15,000 \u03bcS\/cm) such as saltwater bays, or to detect salinity events such as upwelling, rainstorm, and discharge events. Data from this logger can be used with data from the <a href=\"\/products\/data-loggers\/u26-001\" rel=\"noopener\" target=\"_blank\">HOBO U26 Dissolved Oxygen Logger<\/a> for monitoring percent dissolved oxygen saturation.<\/p>\r\n\r\n<p><strong>Note:<\/strong> When monitoring salinity in waters with more than \u00b15,000 uS\/cm variation, refer to the accuracy shown in Plot C in the product specifications to determine if the accuracy is acceptable for your needs. Monthly field calibration readings are typically required to achieve the best accuracy.<\/p>\r\n","applications":["Environmental Research & Protection","Environmental Compliance","Renewable Energy","Water Resource Management","Aquatic Ecology","Water Quality & Compliance","Hydrology & Groundwater Monitoring","Watershed Management","Wetland & Stormwater","Dam Management","Building Performance","Construction Compliance"],"brand":"HOBO","communication":"Optic\/USB","compatible_items":{"Accessory":{"Data_Offload_Base_Stations_Shuttles_Couplers":{"items":["COUPLER2-C","U-DTW-1"]},"Protective_Covers_and_Boots":{"items":["U22-U24-CAP"]},"Protective_Enclosures":{"items":["HOUSING-U2X"]},"Stainless_Steel_Cable_Crimps":{"items":["CABLE-1-300","CABLE-1-50","CABLE-1-CRIMP"]},"Well_Caps":{"items":["WELL-CAP-01"]},"Compliance_Certificates":{"items":["COMPLIANCE CERT"]},"Accessories":{"items":["ME-BP"]}},"Required Communications":{"Data_Offload_Base_Stations_Shuttles_Couplers":{"items":["BASE-U-4","U-DTW-1"]}},"Required Software":{"Graphing_Analysis":{"items":["BHW-PRO-DLD","BHW-PRO-USB"]}}},"compliance_marks":["Conformit\u00e9 Europ\u00e9ene (CE)"],"country":"US","customers_also_bought":["MX2001","U-DTW-1","U20L-0x","U26-001"],"field_documents":[{"nid":9496},{"nid":10351}],"environment":["Water"],"important_information":"Requires HOBOware Pro software and either a U-DTW-1 Waterproof Shuttle or the Base-U-4 Optic USB Base Station for configuration and data offload. Please see compatible items below.","logger_sensor_type":"integrated_sensors","measurement":["Conductivity\/Salinity ","Water Temperature "],"media_remote_videos":["https:\/\/www.youtube.com\/watch?v=HsZ3uYWyQNM"],"not_a_sku":"0","parcel_status":"default","product_battery":"factory_replacement","product_family_series":"U24","features":"<ul>\n\t<li>\u200bNon-contact sensor provides long life<\/li>\n\t<li>Easy access to sensor for cleaning and shedding air bubbles<\/li>\n\t<li>Two user-selectable ranges provide measurements from 100 to 55,000 uS\/cm.<\/li>\n\t<li>Delrin housing will not corrode in saltwater<\/li>\n\t<li>HOBOware Pro software enables start\/end-point calibration to compensate for any fouling and provides easy conversion to specific conductance and salinity using the Practical Salinity Scale 1978 (PSS-78)<\/li>\n\t<li>USB optical interface provides high-speed, reliable salinity data offload in wet environments<\/li>\n\t<li>Compatible with the HOBO Waterproof Shuttle for easy and reliable data retrieval and transport<\/li>\n\t<li>Non-contact sensor with titanium pentoxide coating keeps the sensor from coming in contact with the water, thereby preventing tarnishing or corrosion associated with traditional electrode sensors; sensor coating is inert, so fouling can be wiped off easily<\/li>\n<\/ul>\n","product_price":"1075.00","specifications":[{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"BLANK","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Measurements","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Actual Conductivity, Temperature, Specific Conductance at 25C (calculated), Salinity (calculated using PSS-78, the Practical Salinity Scale 1978)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Conductivity Measurement Ranges","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Low range: 100 to 10,000 uS\/cm"},{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"High range: 5000 to 55,000 uS\/cm"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Conductivity Calibrated Range - Temperature Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"41\u00b0 to 95\u00b0F","field_spec_metric_value":"5\u00b0 to 35\u00b0C"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Conductivity Extended Ranges","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Low range: 100 to 10,000 uS\/cm"},{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"High range: 5000 to 55,000 uS\/cm"},{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"(readings below these ranges reported as 0)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Temperature Measurement Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"28\u00b0 to 97\u00b0F","field_spec_metric_value":"-2\u00b0 to 36\u00b0C"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Specific Conductance Accuracy (in Calibrated Range using Conductivity Assistant and Calibration Measurements)","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Low range: 3% of reading or 50 \u00b5S\/cm, whichever is greater"},{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"High range: 5% of reading, in waters within a range of \u00b13,000 \u00b5S\/cm; waters with greater variation can have substantially greater error"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Conductivity Resolution","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"2 uS\/cm (typical)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Temperature Accuracy","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"0.1\u00b0C (0.2\u00b0F) at 25\u00b0C (77\u00b0F)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Temperature Resolution","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"0.02\u00b0F","field_spec_metric_value":"0.01\u00b0C"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Conductivity drift","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Up to 12% sensor drift per month, exclusive of drift from fouling. Monthly start- and end-point calibration should be used with the HOBOware Conductivity Assistant to achieve the specified Specific Conductance accuracy."}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Response time","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"1 second to 90% of change (in water)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Operating range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"-2\u00b0 to 36\u00b0C (28\u00b0 to 97\u00b0F) \u2013 non-freezing"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Memory","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"18,500 temperature and conductivity measurements when using one conductivity range; 11,500 sets of measurements when using both conductivity ranges (64 KB total memory)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Sample rate","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"1 second to 18 hrs, fixed or multiple-rate sampling with up to 8 user-defined sampling intervals"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Clock accuracy","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"+\/- 1 minute per month"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Battery life","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"3 years (@ 1 min logging)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Maximum depth","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"225'","field_spec_metric_value":"70 m"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Weight","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"193 gm (6.82 ounces), buoyancy in freshwater: -59.8 gm (-2.11 ounces)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Size","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"3.18 cm diameter x 16.5 cm, with 6.3 mm mounting hole (1.25\" diameter x 6.5\", \u00bc\" hole)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Wetted housing materials","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Delrin\u00ae, epoxy, stainless steel retaining ring, polypropylene, Buna rubber O-ring, titanium pentoxide (inert coating over sensor) \u2013 all materials are suitable for long-term use in saltwater."}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Environmental Rating","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"IP68"}]}]}],"product_status":"active","product_type":"Data Loggers","search_keys":"water temperature","solution":["Stand-alone Data Loggers ","Stand-alone Optical Data Loggers ","Waterproof Stand-alone Data Loggers "],"warranty":"1","warranty_premium":"1","whats_in_the_box":["HOBO U24-002-C Conductivity Data Logger","Communications window protective cap"],"wireless":"non_wireless","digital_item":"0"},[{"nid":"9496","uuid":"4b47dbef-8bee-44f5-959f-1576c1e13b2c","vid":"10341","langcode":"und","revision_timestamp":"1645725751","status":"1","title":"HOBO U24 Conductivity Logger (U24-002-C) User's Manual","created":"1369754981","changed":"1645725751","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/16844-man-u24-002-c","pid":"18436","langcode":"und"},"archive_resource":"0","associated_products":["U24-002-C"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/16844-G%20U24-002-C%20Manual.pdf","German":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/18521-E%20U24-002-C%20Manual%20German.pdf"},"documentation_id":"16844-MAN-U24-002-C","documentation_is_datasheet":"0","resource_type":"Documentation"},{"nid":"10351","uuid":"31ae94b5-3d51-4f72-81b1-e12e1ef23b46","vid":"11196","langcode":"und","revision_timestamp":"1645725702","status":"1","title":"HOBO U24 Conductivity Logger (U24-001 and U24-002-C) Quick Start","created":"1516404564","changed":"1645725702","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/22140-man-u24-qsg","pid":"20941","langcode":"und"},"archive_resource":"0","associated_products":["U24-001","U24-002-C"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/22140-B%20MAN-U24-QSG-web.pdf"},"documentation_id":"22140-MAN-U24-QSG","documentation_is_datasheet":"0","documentation_short_title":"HOBO U24 Quick Start","resource_type":"Documentation"}]]
U24-002-C
HOBO Saltwater Conductivity/Salinity Data Logger
A cost-effective data logger for measuring salinity, conductivity, and temperature in saltwater environments with relatively small changes in salinity (±5,000 μS/cm) such as saltwater bays, or to detect salinity events such as upwelling, rainstorm, and discharge events. Data from this logger can be used with data from the HOBO U26 Dissolved Oxygen Logger for monitoring percent dissolved oxygen saturation.
Note: When monitoring salinity in waters with more than ±5,000 uS/cm variation, refer to the accuracy shown in Plot C in the product specifications to determine if the accuracy is acceptable for your needs. Monthly field calibration readings are typically required to achieve the best accuracy.