[{"sku":"UX90-001","title":"HOBO State Data Logger","subtitle":null,"variant_product_name":null,"unit_price":"160.00","brands":["HOBO"],"region":null,"service_plans":[],"parcel_length":"2.00","parcel_width":"1.25","parcel_height":"3.00","parcel_weight":"0.20","sellable":true,"published":true,"product_page_url":"\/products\/data-loggers\/ux90-001","nid":"11731","product_description":"<p>Records state changes, electronic pulses, and mechanical or electrical contact closures from external sensing devices. Ideal for monitoring energy consumption, mechanical equipment operation, and water and gas flow.<\/p>\r\n\r\n<p>Item number UX90-001M has been discontinued.<\/p>\r\n","applications":["Environmental Research & Protection","Renewable Energy","Building Performance","HVAC\/R Monitoring Systems for Indoor Environmental Quality (IAQ & IEQ)","Energy Monitoring","Indoor Environment"],"battery_replacement":"HRB-TEMP-1","brand":"HOBO","communication":"USB","compatibility_callout":["HOBOware"],"compatible_items":{"Accessory":{"Compliance_Certificates":{"items":["COMPLIANCE CERT"]},"Accessories":{"items":["ME-BP"]}},"Communications":{"Communication_Cables":{"items":["CABLE-USBMB"]}},"Maintenance":{"Batteries":{"items":["HRB-TEMP-1"]}},"Required Software":{"Graphing_Analysis":{"items":["BHW-PRO-DLD","BHW-PRO-USB"]}},"Sensor":{"Kilowatt_Hours":{"items":["T-WNB-3D-240","T-WNB-3D-480","T-WNB-3Y-208"]},"Motor_On_Off":{"items":["CSV-A8"]},"Water_Flow":{"items":["T-MINOL-130-NL"]}}},"country":"US","customers_also_bought":["CSV-A8","T-WNB-3D-240","T-WNB-3D-480"],"field_documents":[{"nid":9681},{"nid":10061}],"environment":["Indoor"],"important_information":"Requires HOBOware software and a USB cable. (Note: A USB-A to USB-B mini cable is included w\/HOBOware Pro USB Drive software purchase). See compatible items below.","logger_sensor_type":"external_sensors","measurement":["Event ","Kilowatt Hours (kWh) ","Motor On\/Off ","Pulse Input ","Runtime ","State Open\/Closed ","Water Flow "],"media_remote_videos":["https:\/\/www.youtube.com\/watch?v=9sMdkJExl2U","https:\/\/www.youtube.com\/watch?v=dXuUrddvVtY"],"not_a_sku":"0","parcel_status":"default","product_battery":"onset_battery","product_family_series":"UX90","features":"<ul>\n\t<li>One logger with four recording modes<\/li>\n\t<li>Internal reed switch can be used to determine when a door or window is open or closed<\/li>\n\t<li>Compatible with a wide range of external sensors<\/li>\n\t<li>Ships with 2.5 mm input cable<\/li>\n\t<li>Compatible with HOBOware and HOBOware Pro software for logger setup and graphing & analysis<\/li>\n<\/ul>\n","product_price":"160.00","specifications":[{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"Internal Sensor","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Maximum State, Event, Runtime Frequency","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"1 Hz"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Preferred Switch State","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"No magnet present (normally open)"}]}]},{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"External Input","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"External Contact Input","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Electronic solid state switch closure or logic driven voltage output"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"0 to 3 V DC (USB powered), 0 to 2.5 V DC (battery powered)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Maximum Pulse Frequency","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"50 Hz"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Maximum State, Event, Runtime Frequency","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"1 Hz"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Pulse, Event Lockout Time","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"0 to 1 second in 100 ms steps"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Solid State Switch Closure","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Input Low: < 10 K\u2126; Input High: > 500 K\u2126"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Internal Weak Pull-Up","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"100 K\u2126"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Input Impedance","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Solid state switch closure: 100 K\u2126 pull up"}]}]},{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"Logger","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Resolution","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Logging Rate","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"1 second to 18 hours, 12 minutes, 15 seconds"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Memory Modes","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Wrap when full or stop when full"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Start Modes","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"Immediate, push button, date & time, or next interval"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Stop Modes","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"When memory full, push button, or date & time"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Time Accuracy","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"\u00b11 minute per month at 25\u00b0C (77\u00b0F) (see Plot A)"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Power Source","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"One 3V CR2032 lithium battery and USB cable"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Battery Life","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"1 year, typical with logging intervals greater than 1 minute and normally open contacts"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Memory","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"UX90-001: 128 KB (84,650 measurements, maximum)"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"UX90-001M: 512 KB (346,795 measurements, maximum)"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Download Type","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"USB 2.0 interface"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Full Memory Download Time","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"10 seconds for 128 KB; 30 seconds for 512 KB"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Logger Operating Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"Logging: -20\u00b0 to 70\u00b0C (-4\u00b0 to 158\u00b0F); 0 to 95% RH (non-condensing)"},{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"Launch\/Readout: 0\u00b0 to 50\u00b0C (32\u00b0 to 122\u00b0F) per USB specification"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"LCD","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"LCD is visible from: 0\u00b0 to 50\u00b0C (32\u00b0 to 122\u00b0F); the LCD may react slowly or go blank in temperatures outside this range"}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Size","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"1.44 x 2.34 x 0.6 in.","field_spec_metric_value":"3.66 x 5.94 x 1.52 cm"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Weight","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_imperial_value":"0.81 oz","field_spec_metric_value":"23 g"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Environmental Rating","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_value":"IP50"}]}]},{"type":"Simple text","revision_default":"1","field_description":"<div style=\"display:inline-block;\">\n<article class=\"media media--type-image media--view-mode-default media--orientation-unset\" style=\"float:left; margin-right:2rem;\" data-mark=\"CE\">\n \n \n <div class=\"field field--name-field-media-image field--type-image field--label-visually_hidden\">\n <div class=\"field__label visually-hidden\">Image<\/div>\n <div class=\"field__item field__item__odd field__item__first field__item__last\"> <img loading=\"lazy\" src=\"\/sites\/default\/files\/2022-10\/ce-mark.png\" width=\"27\" height=\"19\" alt=\"CE Compliance Mark\" typeof=\"foaf:Image\" class=\"img-fluid\">\n\n<\/div>\n <\/div>\n\n <\/article>\n\n<\/div>"}],"product_status":"active","product_type":"Data Loggers","solution":["Stand-alone Data Loggers ","Stand-alone USB Data Loggers "],"warranty":"1","warranty_premium":"1","whats_in_the_box":["HOBO UX90-001x State Data Logger","2.5 mm input cable","Command\u2122 strip","Double-sided tape","Hook & loop strap","Magnet with 2 screws"],"wireless":"non_wireless","digital_item":"0"},[{"nid":"9681","uuid":"16b690cd-0633-4f98-bafc-69b5f49b1190","vid":"10526","langcode":"und","revision_timestamp":"1645725760","status":"1","title":"HOBO State Data Logger (UX90-001, UX90-001M) User's Manual","created":"1326807713","changed":"1645725760","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/15430-f-ux90-001-manual","pid":"18956","langcode":"und"},"archive_resource":"0","associated_products":["KIT-UX90-KWH","UX90-001","UX90-001M-RETIRED"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/15430-G%20UX90-001%20Manual.pdf","German":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/18495-B%20UX90-001%20Manual%20German.pdf","Japanese":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/18496-A%20UX90-001%20Manual%20Japanese.pdf"},"documentation_id":"15430-F-UX90-001-Manual","resource_type":"Documentation"},{"nid":"10061","uuid":"3c862735-42d9-4aa0-8b43-52b043a7688a","vid":"10906","langcode":"und","revision_timestamp":"1645725720","status":"1","title":"Quick Start for the HOBO\u00ae U-Series Data Logger","created":"1462555541","changed":"1645725720","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/16125-man-u-qsg-web","pid":"20046","langcode":"und"},"archive_resource":"0","associated_products":["U12-001","U12-006","U12-008","U12-011","U12-012","U12-013","U12-014","U12-015","U12-015-02","U12-015-03","U14-001","U14-002","UX100-001","UX100-003","UX100-011A","UX100-014M","UX100-023A","UX120-006M","UX120-014M","UX120-017","UX120-017M","UX120-018","UX90-001","UX90-001M-RETIRED","UX90-002","UX90-004","UX90-004M-RETIRED","UX90-005x","UX90-005M-RETIRED","UX90-006","UX90-006M-RETIRED"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/2023-03\/16125-F%20MAN-U-QSG-web.pdf","German":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/20691-B%20MAN-U-QSG-G-web.pdf"},"documentation_id":"16125-MAN-U-QSG-web","documentation_is_datasheet":"0","resource_type":"Documentation"}]]
UX90-001
HOBO State Data Logger
Records state changes, electronic pulses, and mechanical or electrical contact closures from external sensing devices. Ideal for monitoring energy consumption, mechanical equipment operation, and water and gas flow.
Item number UX90-001M has been discontinued.
Compatible with
Not sure this is the right logger?
Compare Loggers
Talk to an Application Expert
Specifications
Documents
Compatible Items
What's Included
Customers Also Bought
Frequently Asked Questions
Related Products
Related Resources
Recently Viewed
!