[{"sku":"S-UCD-M006","title":"Contact Closure Pulse Input Adapter - 6 meters Sensor","subtitle":null,"variant_product_name":null,"unit_price":"125.00","brands":["HOBO"],"region":null,"service_plans":[],"parcel_length":"4.25","parcel_width":"2.25","parcel_height":"5.75","parcel_weight":"0.55","sellable":true,"published":true,"product_page_url":"\/products\/sensors\/s-ucd-m006","nid":"12326","product_description":"<p>Connects sensors with pulse outputs to data loggers with smart-sensor inputs. Compatible with contact closures, such as tipping-bucket rain gauges or reed switches with a maximum input frequency of 2 Hz (2 pulses per second), and a preferred switch-type of normally-open. <a data-entity-substitution=\"canonical\" data-entity-type=\"node\" data-entity-uuid=\"34c982c9-4003-4cf7-8d65-a6ae3eca1df4\" href=\"\/node\/7931\" rel=\"noopener\" target=\"_blank\">See how the pulse recorder works<\/a>.<\/p>\r\n","add_on_products":{"items":["ZIP-KIT"]},"applications":["Environmental Research & Protection","Building Performance","HVAC\/R Monitoring Systems for Indoor Environmental Quality (IAQ & IEQ)","Energy Monitoring","Indoor Environment","Shipping & Storage Monitoring","Agricultural Monitoring","Agricultural Research","Irrigation & Water","Crop Production","Orchard & Vineyard","Precision Livestock"],"brand":"HOBO","compatible_items":{"Data Logger":{"USB_Data_Loggers_requires_external_sensors":{"items":["H21-USB","H22-001","U30-NRC"]},"USB_w_external_sensors":{"items":["U30-NRC-SYS-C"]},"Web_based_Monitoring_Systems_via_remote_communication":{"items":["RX2100-WL","RX3000"]}},"Sensor":{"Water_Flow":{"items":["T-MINOL-130-NL"]}},"Accessory":{"Compliance_Certificates":{"items":["COMPLIANCE CERT"]},"Extension_Cables":{"items":["S-EXT-CASE2","S-EXT-M002","S-EXT-M005","S-EXT-M010","S-EXT-M025"]}}},"country":"US","field_documents":[{"nid":9276}],"environment":["Indoor","Outdoor"],"measurement":["Pulse Input ","Water Flow "],"not_a_sku":"0","parcel_status":"default","features":"<ul style=\"line-height: 20.7999992370605px;\">\n\t<li>Plug-n-play adapter for pulse output sensors<\/li>\n\t<li>Automatically recognized by H21, H22, U30, and RX Series data loggers<\/li>\n\t<li>Compatible with contact closures, such as tipping-bucket rain gauges or reed switches with a maximum input frequency of 2 Hz (2 pulses per second)<\/li>\n<\/ul>\n","product_price":"125.00","specifications":[{"type":"Simple text","revision_default":"1","field_description":"<p><strong>Maximum input frequency:<\/strong> 2 Hz (2 pulses per second)<br>\n<strong>Measurement range: <\/strong>0 \u2013 65,533 pulses per logging interval<br>\n<strong>Resolution:<\/strong> 1 pulse<br>\n<strong>Lockout time:<\/strong> 327 ms \u00b1 10%<br>\n<strong>Recommended input type:<\/strong> Mechanical contact closure (example: reed switch in a tipping-bucket rain gauge)<br>\n<strong>Preferred switch state:<\/strong> Active low input Normally open<br>\n<strong>Edge detection: <\/strong>Falling edge, Schmitt Trigger buffer (logic levels: low \u2264 0.6 V, high \u2265 2.7 V)<br>\n<strong>Minimum pulse width: <\/strong>1 ms<br>\n<strong>Input\/output impedance:<\/strong> 100 K\u03a9<br>\n<strong>Open circuit input voltage:<\/strong> 3.3 V<br>\n<strong>Maximum input voltage:<\/strong> 3.6 V<br>\n<strong>User connection:<\/strong> 24 AWG wires, 2 leads: white(+), black(-)<br>\n<strong>Operating temperature range: <\/strong>-40\u00b0 to 75\u00b0C (-40\u00b0 to 167\u00b0F)\"<br>\n<strong>Overall cable length:<\/strong> 6.5 m (21 ft.)<br>\n<strong>Housing:<\/strong> Weatherproof PVC housing protects input adapter electronics<br>\n<strong>Housing dimensions: <\/strong>14 x 0.95 cm (5.5 x 0.375 in.)<br>\n<strong>Weight: <\/strong>310 g (11 oz.)<br>\n<strong>Bits per sample: <\/strong>16<br>\n<strong>Number of data channels:<\/strong> 1<br>\n<strong>Measurement averaging option:<\/strong> No (reports the number of pulses over the logging interval)<\/p>"}],"product_status":"active","product_type":"Sensors","warranty":"1","warranty_premium":"1","digital_item":"0"},[{"nid":"9276","uuid":"81af014d-9203-4288-9d7b-07b29ed02f8c","vid":"10121","langcode":"und","revision_timestamp":"1645725808","status":"1","title":"Pulse Input Adapter (S-UCC-M00x, S-UCD-M00x) User's Manual","created":"1202420115","changed":"1645725808","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/13577-man-s-ucx","pid":"17876","langcode":"und"},"archive_resource":"0","associated_products":["S-UCC-M001","S-UCC-M006","S-UCD-M001","S-UCD-M006"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/resources-documents\/13577-F%20MAN-S-UCx.pdf"},"documentation_id":"13577-MAN-S-UCx","documentation_is_datasheet":"0","resource_type":"Documentation"}]]
Connects sensors with pulse outputs to data loggers with smart-sensor inputs. Compatible with contact closures, such as tipping-bucket rain gauges or reed switches with a maximum input frequency of 2 Hz (2 pulses per second), and a preferred switch-type of normally-open. See how the pulse recorder works.