[{"sku":"W-DO","title":"Dissolved Oxygen Sensor","subtitle":null,"variant_product_name":null,"unit_price":"1099.00","brands":["HOBO"],"region":null,"service_plans":[],"parcel_length":"13.00","parcel_width":"5.00","parcel_height":"2.00","parcel_weight":"0.50","sellable":true,"published":true,"product_page_url":"\/products\/sensors\/w-do","nid":"21621","product_description":"<p>The dissolved oxygen sensor is an interchangeable sensor that works with HOBO MX800 Series Water Loggers to measure dissolved oxygen and temperature.<\/p><p>The DO sensor can be attached directly to the fully submersible MX801 model, or attached via cable to the direct read MX802 model, which doesn\u2019t require having to pull the sensor out of the water to download data.<\/p><p>When this sensor is connected to a HOBO MX800 logger that also has a conductivity or CTD sensor attached, the logger can record salinity-adjusted DO directly. With this sensor attached to the HOBO MX802 direct read model, the logger can calculate DO percent saturation directly. When used with fully submersible HOBO MX801 model, a barometric logger data file (from either an MX802 or <a href=\"https:\/\/www.onsetcomp.com\/products\/data-loggers\/mx2001\">MX2001<\/a> logger) is needed to calculate DO percent saturation, for post-processing in the HOBOconnect app. In waters with changing salinity, the logger must also have a salinity sensor attached or you will need an MX800 salinity data file to get DO percent saturation.<\/p>","applications":["Water Resource Management"],"brand":"HOBO","communication":"Bluetooth","compatibility_callout":["HOBOconnect"],"compatible_items":{"Accessory":{"Accessories":{"items":["W-ADAPT-2","CABLE-W-1.0","CABLE-W-2.0","CABLE-W-5.0","CABLE-W-010","CABLE-W-015","CABLE-W-030","CABLE-W-060","U26-GUARD-2"]}},"Data Logger":{"Data Loggers":{"items":["MX80x"]}},"Maintenance":{"Replacement_Parts":{"items":["RDO-CAP-1"]},"Calibration_Solution":{"items":["U26-CAL-SOL"]}}},"compliance_marks":["Conformit\u00e9 Europ\u00e9ene (CE)","UK Conformity Assessed (UKCA)"],"country":"US","field_documents":[{"nid":22141}],"environment":["Water"],"important_information":"Requires a HOBO MX801 or MX802 Data Logger, the HOBOconnect app, and a compatible mobile device or Windows computer. System requirements for the app can be found at the bottom of our HOBOconnect software page., basic_html","measurement":["Dissolved Oxygen "],"not_a_sku":"0","page_type":"add-to-cart","primary_measurement":"Dissolved Oxygen","product_family_series":"MX800","features":"<ul>\n\t<li>User-replaceable DO cap lasts 2 years or more<\/li>\n\t<li>High accuracy measurements, even without calibration<\/li>\n\t<li>Get salinity-adjusted DO directly when used with conductivity sensor (W-CT or W-CTD), no need for post-processing<\/li>\n\t<li>Direct DO percent saturation data, no need for post-processing (when used with MX802)<\/li>\n\t<li>Easy calibration with included calibration boot \u2013 saves time<\/li>\n\t<li>1\u201d diameter for use in narrow wells (with cable to MX802 above the well)<\/li>\n\t<li>PVC housing holds up in saltwater<\/li>\n<\/ul>","product_price":"1099.00","specifications":[{"type":"Product Specifications","revision_default":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"Dissolved Oxygen","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Optical Sensor ","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"(dynamic luminescence quenching)"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Measurement Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"0 to 60 mg\/L; 0-600% Saturation"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Accuracy","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"Out-of-box: \u00b10.2 mg\/L (typical) over the range of 0 to 20 mg\/L"}]},{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"\u00b14% over the range of 20 to 60 mg\/L"}]},{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"With user calibration: \u00b10.1 mg\/L over the range of 0 to 20 mg\/L; \u00b12% over the range of 20 to 60 mg\/L"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Resolution","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"0.01 mg\/L"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Sensor Drift","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"Accuracy is maintained for 2 years; aside from the effects of fouling"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Response Time","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"To 90% in less than 45 sec"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"DO Sensor Cap Life","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"2 years; after this the sensor will continue operate, but possibly with less accuracy"}]}]}]},{"type":"Product Specifications","revision_default":"1","revision_translation_affected":"1","field_hide_in_compare":"0","field_hide_on_specs_tab":"0","field_specification_group_label":"Temperature","field_specification_items":[{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Temperature Measurement\/Operating Range","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"-5 to 50\u00b0C (23 to 104\u00b0F), non-freezing"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Temperature Accuracy","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"0.15\u00b0C (0.27\u00b0F)"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Temperature Resolution","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"0.01\u00b0C (0.04\u00b0F)"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Response Time","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"To 90% in less than 15 minutes"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Logging Rate","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"When using this sensor, the maximum logging rate is 1 min "}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Depth Rating","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"IP-68, waterproof to 100 m (328 ft) - must be attached to logger and have DO sensor cap installed"}]}]},{"type":"Product Specifications - Item","revision_default":"1","field_specification_label":"Wetted Materials","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","field_spec_single_value":"Black Delrin\u00ae, PVC, EPDM o-rings, rated for saltwater use"}]}]},{"type":"Product Specifications - Item","revision_default":"1","revision_translation_affected":"1","field_specification_label":"Size","field_specification_values":[{"type":"Product Specification - Value","revision_default":"1","revision_translation_affected":"1","field_specification_measurement":[{"type":"Product Specification - Measurement","revision_default":"1","revision_translation_affected":"1","field_spec_code_markup":"Length: 13in<br>\r\nWidth: 5in<br>\r\nHeight: 2in"}]}]}]}],"product_status":"active","product_type":"Sensors","search_keys":"do","warranty":"0","warranty_premium":"0","whats_in_the_box":["Dissolved oxygen sensor","Dissolved oxygen sensor cap","Calibration boot and sponge"],"digital_item":"0"},[{"nid":"22141","uuid":"b2b90e2e-9fbe-46a0-94ac-4e7dbe4d4328","vid":"81341","langcode":"en","revision_timestamp":"1729184474","status":"1","title":"MX800 Series User Guide","created":"1712598075","changed":"1729184474","promote":"0","sticky":"0","default_langcode":"1","revision_default":"1","revision_translation_affected":"1","path":{"alias":"\/resources\/documentation\/mx800-series-user-guide","pid":"55356","langcode":"en"},"archive_resource":"0","associated_products":["MX80x"],"brand":"HOBO","documentation_files":{"English":"https:\/\/dev-d9.onsetcomp.com\/sites\/default\/files\/2024-10\/25707-B%20HOBO%20MX800%20Series%20User%20Guide.pdf"},"documentation_hoboconnect":"0","documentation_intemp_app":"0","documentation_is_datasheet":"0","hoboconnect_docs_sorting":"0","hobomobile_docs_sorting":"0","intemp_cx_docs_sorting":"0","product_family_series":"MX800","resource_type":"Documentation"}]]
W-DO
Dissolved Oxygen Sensor
The dissolved oxygen sensor is an interchangeable sensor that works with HOBO MX800 Series Water Loggers to measure dissolved oxygen and temperature.
The DO sensor can be attached directly to the fully submersible MX801 model, or attached via cable to the direct read MX802 model, which doesn’t require having to pull the sensor out of the water to download data.
When this sensor is connected to a HOBO MX800 logger that also has a conductivity or CTD sensor attached, the logger can record salinity-adjusted DO directly. With this sensor attached to the HOBO MX802 direct read model, the logger can calculate DO percent saturation directly. When used with fully submersible HOBO MX801 model, a barometric logger data file (from either an MX802 or MX2001 logger) is needed to calculate DO percent saturation, for post-processing in the HOBOconnect app. In waters with changing salinity, the logger must also have a salinity sensor attached or you will need an MX800 salinity data file to get DO percent saturation.